Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. EMC Operation is subject to the following two conditions: 1 This device may not cause harmful interference, and 2 This device must accept any Compliance interference received, including interference that may cause undesired operation. Slide the battery cover off. Be sure that the release tab locks into place. Surge protection outlets provide protection from power surges or spikes.
Monitor the UPS for power usage and power events. Warranty The standard warranty is 3 years in the USA and Canada, 2 years in all other regions from the date of purchase.
LEDs flash alternately. The Back-UPS is not connected to Make sure the power cord is securely connected to utility power, there is no utility power the wall outlet, and that there is utility power available at the wall outlet, or the available at the wall outlet. Where applicable, utility power is experiencing a check that the wall outlet is switched on.
The battery is not connected. Connect the battery. In the event that the Back-UPS receives no utility power and the battery is connected, a cold-start can be initiated.
Connected equipment loses power A Back-UPS overload condition has Remove all nonessential equipment connected to occurred. One at a time reconnect equipment to the Back-UPS. Connected equipment does not accept The output waveform is intended for computers the step-approximated sine waveform and peripheral devices.
It is not intended for use from the Back-UPS. The Back-UPS may require service. At this point the user should save all open files, and shutdown the computer. When utility power is restored the battery will recharge. At this point the user should save all open remaining runtime. Call a qualified hazard that must be corrected by a electrician to correct the building wiring fault. Leave the Back-UPS connected to utility power for 16 hours while the battery charges to full capacity.
The battery is near the end of useful As a battery ages, the runtime capability decreases. Contact APC at the Web site www. The connection from the Back-UPS to the internet is lost during a power outage The modem has lost power.
Voltage Sensitivity Adjustment optional The Back-UPS detects and reacts to line voltage distortions by transferring to battery backup power to protect connected equipment. If you are using a Mac OSX, use the native shutdown feature to protect your system. See the documentation provided with your computer. The Back-UPS battery charges fully during the first 16 hours while connected to utility power. Do not expect full battery run capability during the initial charge time. Have a qualified electrician correct the building wiring fault.
The standard warranty is 3 years in the USA and Canada, 2 years in all other regions from the date of purchase.
APC standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Technical Support. APC will ship the replacement unit once the defective unit is received by the repair department or cross-ship upon the provision of a valid credit card number. The Back-UPS detects and reacts to line voltage distortions by transferring to battery backup power to protect connected equipment.
In situations where either the Back-UPS or the connected equipment is too sensitive for the input voltage level it is necessary to adjust the transfer voltage. Connect the Back-UPS to a wall outlet. Refer to the table for an explanation of the transfer voltage sensitivity levels. To exit Program mode wait five seconds and all LED indicators will extinguish.
Program mode is no longer active. Review the Troubleshooting section of the manual to eliminate common problems.
Note the model number and serial number and the date of purchase. The model and serial numbers are located on the rear panel of the unit and are available through the LCD display on select models. Service procedures and returns may vary internationally. Refer to the APC Web site for country specific instructions. Pack the unit properly to avoid damage in transit.
Never use foam beads for packaging. Damage sustained in transit is not covered under warranty. The battery may remain in the unit. Return the unit by insured, pre-paid carrier to the address provided by Customer Support.
All other trademarks are property of their respective owners. Connect equipment to the Battery Backup and Surge Protection outlets. During a power outage or other utility problems, the Battery Backup outlets receive power for a limited time from the unit. Connect the supplied USB software interface cable to the data port, and the other end to a computer with access to the internet. Select PowerChute Personal Edition. Then select the appropriate operating system and follow the instructions to download the software.
Load Capacity— The load is indicated by the number of sections illuminated, one to five. If the load exceeds the rated capacity, the Overload symbol will flash off and on. Battery Charge— The battery charge level is indicated by the number of sections illuminated.
When all five blocks are illuminated, the BackUPS is at full charge. When one block is filled, the Back-UPS is near the. Automatic Voltage Regulation —The unit is compensating for extremely low input voltage, but is not using battery power.
System Faults— The system has a fault. The fault number will illuminate on the display interface. Replace Battery— The battery is not connected or is nearing the end of its useful life.
Replace the battery. On Battery— The unit is supplying battery backup power to the connected equipment, it will beep four times every 30 seconds. When the Master device goes into Sleep or Standby mode, or turns OFF, the Controlled device s will shut down as well, saving electricity. Enable the Power-Saving feature. Ask your question here. Provide a clear and comprehensive description of the issue and your question.
The more detail you provide for your issue and question, the easier it will be for other APC Back-UPS owners to properly answer your question. My APC is making the constant high pitched noise. What do I do? The unit is less than a year old. How do I make it stop? APC beeps 4 times every 30 seconds but is plugged into a live outlet. Is the unit defective?